Installation Instructions

Cold Weather Installation Using EternaPrime®, DoubleStick and Gray RoofSeal

Tools required: EternaBond® DoubleStick, EternaBond® RoofSeal and EternaPrime®

After marking the hold cutting it, coat the tape contact once in EternaPrime®. Allow to dry (30 min). Do not use EternaPrime® on PVC. To install EternaBond® on PVC in cold temperatures (40°F or below), go to PVC and EternaBond®.
Put DoubleStick on the foot of the curb (underside).
Set in place and secure it down.
Counter flash the cone with RoofSeal.